We can design, install and maintain all types of fire alarm systems ranging from analogue, wirefree & addressable systems.

We can connect your fire alarm to other devices including boiler shut off valves or door closers as used in Hotels , Nursing Homes , Offices or similar enviroments

 

There are many types of fire alarm systems each suited to different building types and applications. A Fire Alarm System can vary dramatically in both price and complexity, from a single panel with a detector and sounder in a small commercial property to an addressable Fire Alarm System in a multi-occupancy building.

 

The categories of fire alarm systems are "L" if they are designed to protect life, "P" to protect buildings and "M" if they are manual systems.

 

L1 Fire Alarm System - A category L1 system is designed for the protection of life, which has automatic detectors installed throughout all areas of the building including roof spaces and voids with the aim of providing the earliest possible warning. A Category L1 system is likely to be appropriate for residential care premises. Detectors should be installed in nearly all spaces and voids. With category 1 systems the whole of the building is covered apart from minor exceptions.

 

L2 Fire Alarm System - L2 systems are designed for the protection of life, which has automatic detectors installed in escape routes, rooms adjoining escape routes and high hazard rooms. In a medium sized premises (sleeping no more than ten residents) a category L2 system is ideal. These fire alarm systems are identical to an L3 system but with additional detection in an area where there is a high chance of ignition (e.g. kitchen) or where the risk to people is particularly increased (e.g. sleeping risk)

 

L3 Fire Alarm System - L3 systems are designed to give early warning to everyone. Detectors should be placed in all escape routes and all rooms that open onto an escape route. L3 systems provide more extensive cover than L4. The objective is to warn the occupants of the building early enough to ensure that everyone is able to exit the building before escape routes become impassable.

 

L4 Fire Alarm System - L4 systems cover escape routes and circulation areas only. Therefore, detectors will be placed in escape routes, although this may not be suitable depending on the risk assessment or if the size and complexity of a building is increased. Detectors might be sited in other areas of the building, but the objective is to protect the escape route.

 

L5 Fire Alarm System - L5 is all other situations category, e.g. computer rooms, which may be protected with an extinguishing system triggered by automatic detection. L5 systems is the custom category and relate to some special requirement that cannot be covered by any other category.

 

P1 Fire Alarm System - This system is installed throughout the building - the objective being to call the fire brigade as early as possible to ensure that any damage caused by fire is minimised. Small low risk areas can be excepted, such as toilets and cupboards less than 1m².

 

P2 Fire Alarm System - Detection should be provided in parts of the building where the risk of ignition is high and/or the contents are particularly valuable. P2 systems provide fire detection in specified parts of the building where there is either high risk or where business disruption must be minimised.

 

M Fire Alarm System - Manual systems e.g. hand bells, gongs etc, may be purely manual or manual electric, the latter may have call points and sounders. They rely on the occupants of the building discovering the fire and acting to warn others by operating the system. These systems form the basic requirement for places of employment with no sleeping risk.

 

 